To lay down a procedure for Fumigation of Microbiology Lab.

1.0 OBJECTIVE
To lay down a procedure for Fumigation of Microbiology Lab.

2.0 SCOPE
This SOP is applicable to Quality Control Department (Microbiology Lab).

3.0 RESPONSIBILITY
Microbiologist

4.0 ACCOUNTABILITY
Department Head.

5.0 PROCEDURE
5.1 Use safety goggles and hand gloves during fumigation.
5.2 Put ‘OFF’ the A/C unit .
5.3 Take Potassium Permanganate (about 15 gm.) in a petri dish and keep in the area where fumigation is to be carried out.
5.4 Place the petri plate on a polyethene bag.
5.5 Add about 25 ml of 35 % Formaldehyde solution to Potassium Permanganate .
5.6 Immediately close the area.
5.7 Label the area as “Area Under Fumigation” so that nobody enters the room.
5.8 Keep the room under fumigation for a minimum of 8 - 12 hrs.
5.9 Defumigate the room by putting on the A/C unit .

6.0 FREQUENCY :
6.1 once a week and after completion of any civil work.

Hazards of Formaldehyde :
1. It is toxic to inhalation and ingestion and causes irritation to eyes and respiratory tract.
2. Skin contact can cause dermatitis. Also cause skin burns.
3. Exposure to a concentration of 10 to 20 PPM can cause difficulty in breathing.
4. Slightly corrosive in nature, suspected carcinogen.

Fire Hazards :
1. Vapors of Formaldehyde are flammable and may form an explosive mixture with air.
2. It should be stored in a cool and well ventilated area.
3. Avoid storing below 16 Degree C because it forms a polymer ‘Paraformaldehyde’ which is a flammable solid which on heating may evolve a flammable gas and may explode.
Previous Page Next Page

People Searching On This Page:
  • fumigation in laboratory
  • fumigation process for microbiology
  • FORMALIN FUMIGATION IN THE MOLECULAR LAB
  • principle of fumigation process in microbiology
  • how to fumigate lab
  • fumigation in microbiology
  • What is laboratory fumigation
  • fumigation of lab
  • fumigation lab
  • microbiology lab fumigation procedure number
  • microbiology lab fumigation procedure
  • nmt4
  • fumigation of microbiology lab
  • microbiology lab
  • filteration unit used in microbiology lab

Related Pages


PSR/ Medical Rep Dr. Reddys Laboratories Ltd..

PSR/ Medical Rep Dr. Reddys Laboratories Ltd..

Jobs | Medical Representative | Mumbai
Date:
01-May-2011  Views: 11662

1 Communication – In chamber communication. Positive body language in front of the customers.2 Influencing – selling the perception created by the PMT ...
Junior Lab Chemist in Chemical Industry Quality Chemical Industries

Junior Lab Chemist in Chemical Industry Quality Chemical Industries

Jobs | Quality Control | Mumbai
Date:
24-Apr-2011  Views: 6921

Commenced in the Year 1990, involved in Manufacturing of Industrial Waxes, Wax Emulsions, Polymer Additives, Industrial Lube Oil Additives & Specialty ...
Lab Chemist-QA/QC 4 Opening(s) EVEREST SPICES

Lab Chemist-QA/QC 4 Opening(s) EVEREST SPICES

Jobs | Quality Control | Mumbai
Date:
24-Apr-2011  Views: 11217

Everest is the Brand owned by S Narendrakumar @co. for more than 45 years, Everest is the largest selling brand in India and producer of Ground and bl ...
GMP Laboratory Controls

GMP Laboratory Controls

Articles | Quality Assurance | GMP
Date:
24-Apr-2011  Views: 6551

GENERAL REQUIREMENTSThe establishment of any specifications, standards, sampling plans, test procedures or other laboratory control mechanisms require ...
GMP Packaging and Labeling Control

GMP Packaging and Labeling Control

Articles | Quality Assurance | GMP
Date:
24-Apr-2011  Views: 15025

MATERIALS EXAMINATION AND USAGE CRITERIALABELING ISSUANCE PACKAGING AND LABELING OPERATIONS ...
Post Your Comments (No Login Require)
Name : (required)
Email : (required)
Website :

Comment : (required)

22  + 7 =     
Comments
M.Karuppaiya  |  14-Sep-2015 10:00:33 IST
Thank you for the information
PRAVEEN P  |  27-Jun-2018 19:41:08 IST
potassium permanganate and formalin in fumigation will harm the equipments. can you tell me any other fumigation procedure for microbilogy lab especially eco frendly.
vidhya  |  19-Mar-2019 10:58:10 IST
can you give reference for the quantity using in fumigation for formaldehya and potassium permanganate
People Searched About:
Fumigation In Laboratory   |   Fumigation Process For Microbiology   |   FORMALIN FUMIGATION IN THE MOLECULAR LAB   |   Principle Of Fumigation Process In Microbiology   |   How To Fumigate Lab   |   Fumigation In Microbiology   |   What Is Laboratory Fumigation   |   Fumigation Lab   |   Fumigation Of Microbiology Lab   |   Microbiology Lab   |   Filteration Unit Used In Microbiology Lab   |   Microbiology Lab Fumigation With Gas   |   Fumigation Of Potasium Permagnete   |   Fumigation In Microbiology Lab   |   Defumigate   |   Ratio Of Fumication In Microbiologylabs   |   FUMIGATION WITH FORMALIN   |   Fumigation Of Laboratory   |   Fumigation Procedure With Kmno4 And Formaldehyde   |   Formaldehyde Potassium Per Megnate Fumigation In Microbiology Labs   |   Fumigation Process USING Fogger Micro Lab   |  
Google : 5025 times | Yahoo : 20 times | Bing : 1233 times |