To lay down a procedure for Fumigation of Microbiology Lab.

1.0 OBJECTIVE
To lay down a procedure for Fumigation of Microbiology Lab.

2.0 SCOPE
This SOP is applicable to Quality Control Department (Microbiology Lab).

3.0 RESPONSIBILITY
Microbiologist

4.0 ACCOUNTABILITY
Department Head.

5.0 PROCEDURE
5.1 Use safety goggles and hand gloves during fumigation.
5.2 Put ‘OFF’ the A/C unit .
5.3 Take Potassium Permanganate (about 15 gm.) in a petri dish and keep in the area where fumigation is to be carried out.
5.4 Place the petri plate on a polyethene bag.
5.5 Add about 25 ml of 35 % Formaldehyde solution to Potassium Permanganate .
5.6 Immediately close the area.
5.7 Label the area as “Area Under Fumigation” so that nobody enters the room.
5.8 Keep the room under fumigation for a minimum of 8 - 12 hrs.
5.9 Defumigate the room by putting on the A/C unit .

6.0 FREQUENCY :
6.1 once a week and after completion of any civil work.

Hazards of Formaldehyde :
1. It is toxic to inhalation and ingestion and causes irritation to eyes and respiratory tract.
2. Skin contact can cause dermatitis. Also cause skin burns.
3. Exposure to a concentration of 10 to 20 PPM can cause difficulty in breathing.
4. Slightly corrosive in nature, suspected carcinogen.

Fire Hazards :
1. Vapors of Formaldehyde are flammable and may form an explosive mixture with air.
2. It should be stored in a cool and well ventilated area.
3. Avoid storing below 16 Degree C because it forms a polymer ‘Paraformaldehyde’ which is a flammable solid which on heating may evolve a flammable gas and may explode.
Previous Page Next Page

People Searching On This Page:
  • SOP for standard fumigation of Microbiology laboratory
  • how to do lab fumigation
  • lab fumigation process
  • define fumigation in microbiology
  • fumigation of potasium permagnete
  • fumigation in microbiology lab
  • fumigation frequency in microbiology lab
  • fumigation of lab
  • what does fumigating with formaldehyde do
  • fumigation method in microbiology lab
  • sop for difumigation in microbiology laboratory
  • fumigation for microbiology lab brand
  • fumigation in microbiology
  • how to do fumigation of lab
  • sop for fumigation procedure

Related Pages


PSR/ Medical Rep Dr. Reddys Laboratories Ltd..

PSR/ Medical Rep Dr. Reddys Laboratories Ltd..

Jobs | Medical Representative | Mumbai
Date:
01-May-2011  Views: 9940

1 Communication – In chamber communication. Positive body language in front of the customers.2 Influencing – selling the perception created by the PMT ...
Junior Lab Chemist in Chemical Industry Quality Chemical Industries

Junior Lab Chemist in Chemical Industry Quality Chemical Industries

Jobs | Quality Control | Mumbai
Date:
24-Apr-2011  Views: 5990

Commenced in the Year 1990, involved in Manufacturing of Industrial Waxes, Wax Emulsions, Polymer Additives, Industrial Lube Oil Additives & Specialty ...
Lab Chemist-QA/QC 4 Opening(s) EVEREST SPICES

Lab Chemist-QA/QC 4 Opening(s) EVEREST SPICES

Jobs | Quality Control | Mumbai
Date:
24-Apr-2011  Views: 9856

Everest is the Brand owned by S Narendrakumar @co. for more than 45 years, Everest is the largest selling brand in India and producer of Ground and bl ...
GMP Laboratory Controls

GMP Laboratory Controls

Articles | Quality Assurance | GMP
Date:
24-Apr-2011  Views: 4960

GENERAL REQUIREMENTSThe establishment of any specifications, standards, sampling plans, test procedures or other laboratory control mechanisms require ...
GMP Packaging and Labeling Control

GMP Packaging and Labeling Control

Articles | Quality Assurance | GMP
Date:
24-Apr-2011  Views: 11490

MATERIALS EXAMINATION AND USAGE CRITERIALABELING ISSUANCE PACKAGING AND LABELING OPERATIONS ...
Post Your Comments (No Login Require)
Name : (required)
Email : (required)
Website :

Comment : (required)

29  + 1 =     
Comments
M.Karuppaiya  |  14-Sep-2015 10:00:33 IST
Thank you for the information
PRAVEEN P  |  27-Jun-2018 19:41:08 IST
potassium permanganate and formalin in fumigation will harm the equipments. can you tell me any other fumigation procedure for microbilogy lab especially eco frendly.
vidhya  |  19-Mar-2019 10:58:10 IST
can you give reference for the quantity using in fumigation for formaldehya and potassium permanganate
People Searched About:
SOP For Standard Fumigation Of Microbiology Laboratory   |   How To Do Lab Fumigation   |   Lab Fumigation Process   |   Define Fumigation In Microbiology   |   Fumigation Of Potasium Permagnete   |   Fumigation In Microbiology Lab   |   Fumigation Frequency In Microbiology Lab   |   Fumigation Of Lab   |   What Does Fumigating With Formaldehyde Do   |   Fumigation Method In Microbiology Lab   |   Sop For Difumigation In Microbiology Laboratory   |   Lab Fumigation Procedure   |   Fumigation Methods In Microbiology Lab   |   Micor Lab Fumigation Sop   |   Defumigate   |   Ratio Of Fumication In Microbiologylabs   |   FUMIGATION WITH FORMALIN   |   Fumigation Of Laboratory   |   Fumigation Procedure With Kmno4 And Formaldehyde   |   Formaldehyde Potassium Per Megnate Fumigation In Microbiology Labs   |   Fumigation Process USING Fogger Micro Lab   |  
Google : 3800 times | Yahoo : 19 times | Bing : 779 times |